Products for High-Temperature Furnaces
By putting Pt cap at the top, gas is slowed on its way to the thermocouple top. This prevents the thermocouple from degrading and extend its life time (over three times as long has been achieved). This thermocouple is used in glass industry and in the annealing process used for high performance ceramics and chip condensers.
Components
Protective Tubes
Type | Temperature(°C) |
---|
Ceramic protective tube High Grade | 1600 | Ceramic protective tube Grade 1 | 1500 | Ceramic protective tube Grade 2 | 1400 | Quartz protective tube | 1000 |
- *The above temperature indicates operating temperature in which the thermocouple can be used for a long time in air.
Insulating Tubes
Type | Temperature(℃) |
---|
Insulating tube High Grade | 1600 | Insulating tube Grade 1 | 1500 | Insulating tube Grade 2 | 1400 |
- *Above temperature indicates operating temperature in which the thermocouple can be used for a long time in Air.
SUS Collar
Size | Protective tube size |
---|
A |  | Under Φ10mm |
---|
B |  | Under Φ15mm |
---|
C |  | Under Φ21mm |
---|
- *Standard length of SUS collar is 100mm.
- *Various dimensions available.
Connector
Type | Code |
---|
Close |  | MT-7 |
---|
MT-10 | Open |  | J2 Large |
---|
J2 Small |
Compensating Lead Wire
The compensating lead wire is used to connect the thermocouple and the temperature indicator and compensate the error caused by temperature change by connectors. There are various types of lead wires with depending on the type of thermocouple or environment of usage. We’re pleased to suggest a best lead wire appropriate to conditions.
|
|